Liquid line or suction line confusion! - Inspecting HVAC

Sep 06, 2021· The change of state must happen in the evaporator, not in the metering device or in the suction line. Thus Super Heat adjustment is required. We want the gas at the outlet of the evaporator to be 10 degrees F higher than the low side saturation temperature to insure there is no change of state happening outside of the evaporator.

High suction and low discharge pressures

High suction and low discharge pressures This condition is usually due to a fault within the compressor, such as broken valve reeds or incorrect seating of the valve reeds. If the suction reeds are at fault, some of the discharged vapour will be forced back into the suction side of the compressor as the piston reaches the top of its stroke.

Refrigerant line sizing – Part II: suction and discharge

Jan 15, 2018· The suction line consists of Lt=15 m of straight tube with 8 long radius elbows while the discharge line consists of 15 m with 10 standard elbows. Then, determine the lines’ sizes if the condensation temperature becomes 50 °C. Suction From Figure 2, 191.84 kW capacity in 54 mm OD suction line results in a 0.04 K m-1. Thus, from Figure 3, a 50 mm long radius …

Pump suction pipe design considerations

The fitting also has a low side 14mm charge port. The discharge fitting has 3/4"-16 threads for the discharge hose, and 1-14 thread for the compressor fitting. The fitting also has a 16 mm charge port. Please note that if your compressor has the same size fittings on the suction and discharge it is tube-o. See the pictures for samples.

Is Your AC or Pipes Sweating? Here''s What It Means

AC Ductwork: The inside of your ductwork - especially older, poorly insulated, or non-insulated ductwork - can also gather condensation. Toilets: If you see condensation on a toilet that''s not immediately connected with a steamy shower, it means …

Diagnosing A Restricted Liquid Line Can Be Tricky

Nov 26, 2002· Many service technicians often become confused when the liquid line becomes restricted in the refrigeration system. This is because the symptoms often look like an undercharge of refrigerant. This article covers a refrigeration system with a restricted liquid line after the receiver using R-134a as the refrigerant. The refrigeration system is a low temperature …

HVAC Ducting Principles and Fundamentals

Most air conditioning and heating systems require some form of duct work to channel or direct the air to places where the conditioned air is needed. There are many types of ductwork available and often times the ductwork can make a big difference in your utility bills. For that reason, it is

The suction side (low side) and discharge side (high side

sors are known as reciproing, upright or in-line type compressors. The Sanden (Sankyo) and Seltec (Diesel KIKI, Zexel) are rotary types. The suction side (low side) and discharge side (high side) ports are usually stamped with the letters “S” or “D” on the compressors head. COMPRESSORS Table of Contents COMPRESSORS Compressor Related Items

Why are discharge lines smaller than suction lines

Nov 05, 2010· Suction line: 4.5 to 20 m/s Discharge line: 10 to 18 m/s Recommended liquid line velocities: from condenser to receiver: < 0.5 m/s from receiver to evaporator: < 1.5 m/s Higher gas velocities are sometimes found in relatively short suction lines on comfort air-conditioning or other appliions where the operating time is limited

Air-Conditioning Hoses and Fittings - Tubes International

Flexible freon hoses are widely used in air-conditioning systems of various vehicles (cars, machinery, trains, trams) as well as in smaller installations of industrial cooling. In these installations, freon (e.g. R134a, R1234yf) mixed with compressor oil (e.g. PAG synthetic oil) acts as a refrigerant. It circulates in the system where it

Basic Air Conditioning Piping Recommendations – Suction

Jun 19, 2013· Okay — hopefully I’ve made my point that the two factors — suction line pressure loss and suction line velocity –are the most important parts of sizing suction lines for any air conditioning system — either residential of commercial. After my last post, I received this comment from Bruce Porter – Senior Manager of Field Service for UPG – Johnson Controls …

Lowe’s Home Improvement

Shop tools, appliances, building supplies, carpet, bathroom, lighting and more. Pros can take advantage of Pro offers, credit and business resources.

Suction line vs Discharge line - Pump engineering - Eng-Tips

Mar 23, 2012· The Pump Suction line is one (or more)sizes larger than the pump suction nozzle. b). The suction nozzle is one size larger than the discharge nozzle. c). The discharge line is normally one size larger than the discharge nozzle. Example: Suction line size = 8" or 10". Pump suction nozzle size = 6".

Air Conditioner Troubleshooting - Air Conditioning Systems

Suction Frost Air Conditioner Troubleshooting. Air conditioner unit is over capacity. Air filter is clogged. Room temperature is too low. Evaporator coil is dirty. Fan coil motor is rotating in the reverse direction. Fan motor belt loose or slip. Temperature setting of thermostat too low. R.P.M of fan coil blower too low.

A Review of Discharge and Suction Line Oscillation Research

of the compressor suction line. Similarly, Stein and Eibling (20) showed improved compressor performance by tuning the dis­ charge side of the compressor, Thus, significant improvements in compressor thermodynamic performance may be obtained …

How to Loe the High and Low Sides on a Home AC

The low side, or suction line, will be the line connected to the compressor from the top or higher position. It will be cold to the touch and may be wrapped with insulation. This is where freon enters the compressor as a gas. Advertisement.

Is the suction line the high side? - Answers

Dec 14, 2012· Low side is the suction side and will have the larger hose attached to it and the high side is the discharge side and will have the smaller hose.. Ere is the low port for …

HVAC/R Refrigerant Cycle Basics - HVAC School

Mar 01, 2019· The suction line should contain low-pressure superheated suction vapor. It is cool to the touch on an air conditioning system and cold to the touch in refrigeration. Discharge Line = Line Between the Compressor and the Condenser The discharge line should contain high-temperature, high-pressure superheated vapor.

HVAC and Refrigeration Compressor Troubleshooting Chart

Low suction pressure due to a liquid line restriction. Restriction in the discharge line due to physical damage or an internal restriction. This will leave refrigerant in the low side which creates the possibility of flooding on start up. Excessive evaporator coil icing. Superheat setting on expansion valve too low.

Discharge Connection - an overview | ScienceDirect Topics

Roger Legg, in Air Conditioning System Design, 2017. Connections to Plant Items. As with the fan suction and discharge connections (see Chapter 15), duct connections to plant items which produce asymmetrical velocity profiles at the upstream face of the equipment may lead to increased pressure drop, increased noise generation, lower efficiency and moisture carry-over.

(DOC) MEASURING THE COMPRESSOR SUCTION AND …

(See Figure 2.) Attach a pressure/vacuum module to a DMM and set the module to cm/in. Hg. Connect the module at the suction line service port. Close the compressor off from the low side of the system by front seating the suction service valve. Run the compressor for two minutes. Turn off the compressor and observe the reading.

Long Line Piping - US Air Conditioning Distributors

1. Suction line pressure loss due to friction. 2. Suction line velocity for oil return. 3. Liquid line pressure loss due to friction. 4. Liquid line pressure loss (or gain) due to static head. The effect that each of these factors have on a cooling system depends on the orientation of the indoor and outdoor sections;

DUCT SYSTEM DESIGN CONSIDERATIONS

a central supply plenum that feeds a nuer of indi-vidual branch ducts arranged in a generally radial pattern (see Figure 1). It also can be designed and sized so that each individual run leaving the plenum can feed two or more supply outlets. This is fre-quently the case because of the nuer of supply

Air Conditioning - Terms

LIQUID LINE - Pipe or hose connecting condenser to expansion valve. LOW SIDE - That portion of system from orifice in expansion valve through evaporator line or lines through compressor service valve to compressor reed valve. Also called suction side. Back to Top. M. MODULATOR VALVE - Device which limits and maintains minimum pressure in the evaporator.

Refrigerant Piping Installation & Repair; Air Conditioning

Air conditioning refrigerant line defects Refrigerant line insulation requirements & common temperatures Refrigerant line mounting requirements & mechanical damage risks Air conditioning refrigerant piping distances and diameters required Allowable distances between air conditioning compressor and air handler Why & where you will see refrigerant line brazing or soldered …

What is the suction line on an air conditioner? - Quora

The larger one is your suction line and is usually insulated. It returns to the evaporator coil in the smaller line called the liquid line. It is sometimes called the low side of the system because the psi of this line is much lower than the liquid line, called high side, and you check each with different dials on your gauges.

What an A/C Suction hose? Forums

May 29, 2008· The suction hose is on the "supply" side of the freon line to the compressor. The suction hose in the Saturn is attached to the dryer. My suction hose/dryer assely had to be replaced last year. The dryer had developed a crack. The shop first recharged the system with a dye and found the leak. Then, they replaced the hose.

How to Remove a Blockage From a Clogged AC Drain Line

1. For larger blockages, use a wet-vac or air compressor to remove the blockage. If using a wet-vac, suction can be applied to either end of the drain line to remove the clog. If using an air compressor, see step 3. 2. If the cleaning solution or water fills up the drain, a wet-vac can be used to remove the fluid.

A/C Suction Hose | O''Reilly Auto Parts

The suction hose is a low-pressure line in your A/C system. It''s made of a special rubber and carries refrigerant to the compressor from the evaporator. Any physical damage to the suction hose can affect the entire A/C system. Signs of a failing suction hose includes lack of cool air or leaking coolant.

Examining high suction pressure - Hvac Brain -Northrich Parts

May 08, 2017· For any refrigeration cycle/AC unit there are two operating pressures: suction pressure and discharging pressure, high and low settings for each pressure line determined by the manufacturer will stop the unit. Case 1: Insufficient compressor (leaking discharge valve). In other words the compressor can’t provide the needed refrigerant to the evaporator to handle the …